compare the thermocouple and pyrometer,which one is the best?why?
Answer Posted / amsal
each has its own value.
Because pyrometer is used where t/c can not be used.and pyrometer can not take place of t/c.
pyrometer is used to measure the temperature measurment is done without contact or contact can be harmful like in foundries operations as anealing, tempering and melting etc,
there temperature range is higher than t/c range.
T/C is used in process industries commonly to measure temperature.where pyrometer cannot be used.
| Is This Answer Correct ? | 14 Yes | 0 No |
Post New Answer View All Answers
What is difference between differential pressure & delta pressure?
How can we test a bently nevda 3500/42M accelerometer monitor card by simulating it with test equipment?. what king od of signal (milli volts or volts or or resistance ) we should feed in the terminals of the card?
What are the types of control valves available
why we use 3 wire rtd direct wiring for temperature measurement instead of temperature transmitter like bearing temperature
what is the procedure for auto tune in masoneialn 12300 series displacer type transmitter?
What is the difference between uv and ir scanners? and what is the workig principle of both
key exchanges in wpa,wpa2,tls
How to Calibrate Ultrasonic Level Transmitter in field
defination of radial vibration?
Explain signal isolator
How to Calibrate Vortex Flow transmitter in field
What is exact difference between the panel earthing and system earthing in DCS system. What is the value of resistence.
DEAR SIR/MADAM MY NAME IS ARKAPROVA BHATTACHARYYA.I AM A FRESHER INSTRUMENTATION ENGINEER.CAN YOU PLEASE SEND SOME QUESTION PAPERS OF GRADUATE ENGINEER TRAINEE EXAM OF DVC(DAMODAR VALLY CORPORATION).MY EMAIL IDs ARE arka_aec@rediffmail.com.
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
Manipulation of dead wt. tester double piston type.