Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Are generator action and motor action relates to a
particular machine only?

Answer Posted / sudheer

the above said answer is correct and brief explanation is:
IN motor generating action takes place and the generated
emf is what we call as bacf emf which is opposite to given
supply.Even though it is opposite it is advantageous as it
makes motor self governing that is if load increases speed
decreases back emf decreases and load increases to satisfy
load demand same way it decreases load current if load
decreases.

In generator motoring action takes place and torque
produced is called electromagnetic torque which is in
opposite direction to rotation of prime mover.But we rotate
prime mover with speed greater than electromagnetic torque
hence motoring action takes place predominantly.

AUTHOR:sudheer.868@gmail.com

Is This Answer Correct ?    12 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is p.s impedance measurement test in earthing transformer?

2471


hwat type of motor is used in thermal gas turbine hydro nuclear power plants and why

1938


What is installed in PAC that is control the humidity

1556


in basic 2 phase will short means tripping the power but spot welding 2 phase shorting but not tripping it will welded why.....(Q)

2012


What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.

2123


when will be the iocl interview results ifaced the interview on september 8 th

2263


The loads are connected with phase and ground then why current flow as the loads ?

2014


How to design harmonic filter at the project stage without nowing the harmonics levels

2253


How a capacitor discharge weld power supply works? what is the use of a pulse transformer?

2117


what would happen if reactive power (kvar)is increased (more)or decreased (less)? how much exact reactive power should be maintained? and what should be done for that

2316


impliment (AB)`+C to transistor representation

1875


How to Calculate The sag of OPGW in Transmission Line???

3175


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

2172


What is the formula to calculate distribution transformer De-rating on iron losses basis

1902


What is the difference between UPS & inverter ? which UPS is better and whos got the edge ? what is the difference between & inverter ? which UPS is better and whos got the edge 12 V , 24 V , 36 V etc what are the advantages of 12 V, 24 V , 36 V etc and what are the disadvantages of 12 V, 24 V, 36 V etc thanks

1953