Answer Posted / suresh apgenco
isolation transformers are used to isolate faults which
occur on the primary side not to transfer to secondary
side.
| Is This Answer Correct ? | 14 Yes | 0 No |
Post New Answer View All Answers
What is the slip speed?
Is potential difference materials property ..? if yes tnen how.. explain brifly.
sir iam from electrical and electronics branch ,can i appear for the hpcl offline requirtment? if yes please mail me on vikram_raju25@yahoo.co.in
What will happened if the neutral of the (star connected secondry) Xformer disconnected? (if its Above KVA rated one)
hi friends how 3 phase converter functioning ?what is working principle of rotory phase converter ?
1. for eg, capacitor is used for many purposes(it act as filter, oscillator, bypass capacitor, memory storage etc...) 2. Please tell me some example circuits for different uses of capacitor( whenever and whereever and however we used capacitor as a filter, oscillator tuning etc..) 3. similarly for inductor and resistors(it act as what?) and when and how we want to act as like that?, and how we can used these components depends upon our requirments with example circuits and explanation? design to act as these components depends
Igfet is a
What is the function of electron gun used in crt?
How to do maintenance of transformer feeder.
Why a tesa lamp is glow between two phase?
Why to keep capacitor bank off while generator running.
Define stepper motor. What is the use of stepper motor?
what is frequency response?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
I am going to appear for the RRB Chennai Section Engineer online exam. Please send me the question papers from 2001 to date to my mail id:upendrakrishna20@gmail.com,plz send me ,or send any other rrb papers plzzzzzzzzzzzzzzzzzz