Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

If compound Pka is 5 then which buffer you will select ?

Answer Posted / shyam kumar

The thing is u should not use mobile phase pH 5.00. any pH
u can use generally +/- 1.00 unit is preferable. in that
also selection of lowe or higher pH is depending on your
compound nature and noise. in whis pH u have less noise
choose that.

Is This Answer Correct ?    19 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how we can identify the impurity is coming below loq at transfering site?

849


why does used dry caffien in HPLC calibration?

2018


How to calculate coreletion coefficient

1691


what parameters we will consider while developing a HPLC method and how we confirm our HPLC method is valid?

3667


For titration in anhydrous media with perchloric acide, if lack of titrator, Which indicator is been used for replacement. How calculate pH of test solution to choose suitable indicator?

2300


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3526


Loss of linearity in tkn analysis, possible reasons?

1308


when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.

2028


What is a difference between potency and purity?

1191


Why sodium hydroxide used for maintain pH of phosphate buffer

2385


Related substance method equivalency on control sample or spiked sample?

751


Why perchloric acid used for potentiometric titration

2661


what is third integration

1961


4. Describe the operation of the Craig apparatus. Chapter.3 Equilibrium Processes in Separations

2699


if content uniformity passing but dissolution varrying then what is next step?

853