Design steps of one way slab
1. Depth of slab
d= lx/20 * M.F. (M.F. = Modification factor)

Assume the dia. of bar (8, 10, 12) and
Final overall depth
D= d+15+0/2
d= d-15-0/2
2. Effective Span
This is taken as the lesser of the followings
a) Center to center distance between followings
L= lx + t
L= lx + d
3. Load
Consider 1m width of the slab and find out the total udl
a) W = (Self weight + Live Load + Floor finish)
b) Find factor load
Wu = 1.5 * w
4. Factor bending moment
Mu = Wu * l²/8
5. Equating Mu limit to Mu find the depth req. if it is
less than‘d’ than O.K otherwise
Increase D & repeat 2, 3, and 4
Mulimit = Mu
6. Area of main steel
Pt = 50fck/fy (1-√1 – 4.6 Mu / fck bd²)
Ast = Pt/100 *100* d
7. Spacing of main steel
S = Area one bar * 1000/ Ast
Check: - a) 3d
b) 450 mm
8. Distribution Steel
Astd = 0.15 % of Ag -Fe 250 (mild)
= 0.12% of Ag – Fe 415/5000 (torque)
Ag = b.D
9. Spacing of distribution steel
S= Area one bar * 1000/ Astd
Check: - a) 5d
b) 450 mm

10. Check for depth
a) Žv = V/bd
b) Pt —› Zc
c) Zv < Zc …….. No shear reinforcement req.

Is This Answer Correct ?    146 Yes 35 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Process of pcc in wateredug

1788


Which code specifies the specification ofthe construction joints to be provided in the raft slab of a basement which is 6 m deep.what should bethe detail of such a joint?

2028


what is the difference b/w full length and cutting length?

1800


what do you understand by M25 concrete

1918


How to convert 20 dia bar to 16 dia bar in beam without reducing the steel weight

1423






types of laps in column

1900


What is the diff between cad & cadd?

635


what is meant by residual strain?

1785


How to calculate quantity of plum masonry in 1:3:7

2514


what is mean by reestimation?

1348


How to calculate the force on a column of three story building. What should be the base concrete height?.

1641


Scaffolding IS code NO.

1771


Why Vitrified tile are getting pop up.

520


in staad ,why we realease a moment of a member ? what is affect if we realease a moment

1720


how to reduce size of column 450 x 750 to 230 x.... if it is cut in area of bathroom? means it appears in bathroon any shifting or any other option....building is g + 10 and the bathroom is at first floor...

1884