why any inductive load need free wheeling diode?

Answer Posted / jain c

the inductive load saving and releasing energy for a
particular intervals. the free wheeling diode provides the
return path to flow the current saved in the inductive load.

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

explain which quantities change in the starting and the and the running condition in induction motor

940


In which of the following case, the rotating magnetic field is reversed? A regenerative breaking B plugging C dynamic breaking D forward motoring

1499


where reactive power is used

1550


63MVA,220KV/6.9KV Transformer LV side neutral is connected to Earth pit through NGR. Whether this earth pit required to connect with near by below grouding earth mat or it is to be kept separate?

2286


What are the reasons for the parallel operation of transformers?

606






Dear all: Recently we got a question about Interface between PMS and SAP-PM.once we got a update message from PMS.we should set the deletional flag for functional location in SAP system.Is there any FM or BAPI to use?There are only functional location create and change provided by SAP. Best regards!

1575


How to protect sensitive loads such as Dosing pumps inside a factory from voltage surge/voltage fluctuation.

1318


pls someone send me sample question papers along with the key.thanks in advance

1872


i am studying in final year can i allowed for 23rd UES of Indian army

1638


hi plz send me reliance placement papers..i.e electrical technical papers that have been asked in reliance test.

2459


in 132kv substation CRT means

2195


If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?

1674


What is knee point voltage?

666


Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?

1217


An ISP is granted a block of addresses starting with 150.80.0.0/16. The ISP wants to distribute these blocks to 2600 customers as follows. a) 200 medium size businesses; each needs 16 addresses b) 400 small businesses; each needs 8 addresses c) 2000 households; each needs 4 addresses Design the subblocks and give the slash notation for each subblock. Find out how many addresses are still available after these allocations.

6991