Why SF6,VCB,Oil Ckt Breakers are use in HT Side need brief
information ?

Answer Posted / ashoke

Because the air circuit beakers are unable to quench the arc
immediately due to High voltage and current.So a more
efficient arc quenching medium is require like
oil,vacuum,SF6 in side.The HT contains higher voltage level
and the fault current is also higher so a brief description
is needed for choosing the appropriate CB.

Is This Answer Correct ?    7 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the preventive maintence for ht panels and busbars and vcb abd acb's.

1850


Meaning of ingrace protection for motor.for ex IPXY

2339


difference between power surge and switching transient

1524


can anybody tell me that for p.f. Improvment we use capacitor banks but how to decide its capacitance. As we all know how to calculate kvar but what abt capacitance value

1388


If a rotary UPS is in line through grid power; What would be the impact on Power Factor if the load through rotary ups is 25% , 50% , 75% & 100%. Will the power factor reduce with less load?

1416






what is the difference between droop mode and ischnorous mode in thermal powerplant?

2164


what will happen if multimeter(selector switch at DC voltage) and terminal at current is connected to DC supply?

1508


How does zener phenomenon differ from avalanche breakdown?

687


what happens to the water pump if ground water level is slowly decreasing?our water pump is varying from no-load full-load due to this problem

1209


why need to be maintain power factor for industrial customer?

4081


What is the maximum percentage voltage drop (vd%)for a motor control center

1541


How to do cable earhing? whether by grounding Armour to ground or by running extra G.I wire along with cable? which one is preferred mostly amoung them? If the second one is more preferable how many GI wires to be run along with cable (1 or 2)?

1587


What is the effect of atmospheric pressure & Temp; on efficiency of motor? Why NGR(Neutral Grounding Resistor) is used in 132/11 KV Transformer & how? What is the use of Auto T/F in Grid Station?

1423


it is in our knowledge tht right plug of supply of residential suppy system is phase n other is neutral...howevr the battery charger of mobile works in both ways...i mean it is not restricted in only one direction.ny of the holder of charger can hav phase .so y is it not lik tht phase of supply must b connected 2 phase of charger...?

1553


What should be the protection scheme for a 15kw, 3-phase motor working in a lathe machine.

1560