Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why SF6,VCB,Oil Ckt Breakers are use in HT Side need brief
information ?

Answer Posted / ashoke

Because the air circuit beakers are unable to quench the arc
immediately due to High voltage and current.So a more
efficient arc quenching medium is require like
oil,vacuum,SF6 in side.The HT contains higher voltage level
and the fault current is also higher so a brief description
is needed for choosing the appropriate CB.

Is This Answer Correct ?    7 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?

2084


What are the advantage of free wheeling diode in a full wave rectifier?

1183


how to select automotive wire by mathematical equation with given current, vlotage and resistance

2400


can any one suggest paper presentation topies for electrical engg?

2049


what is sevice settings for mccb?How can be it setted?

2071


How test for Ddo vector group test condition?

2514


What types domain of laplace transforms? What behavior can laplace transform predict how the system work?

1210


What is CCT (Correlated Color Temperature) ?

2008


Block diagram of Power line communication?

2361


What happen when change order of CT in GIS feeder?

1695


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2198


132/66kv sub-station procation ?

2309


What range of speed can you get with the armature control method of speed control of d.c. Shunt motor?

1185


what is the difference between "Rotary bypass isolation switch and Normal bypass switch" pls share indepth techs?

2112


How to work definite,over pluxing,revers power,OSR relay

1863