What is the difference between Chromatograhic Purity And
Related substances
Answer Posted / basha
chomatographic purity means which will give purity of both
drug substance,known and unknown peaks
related substance means known impurities where as unknown
impurites we can.t quntify
| Is This Answer Correct ? | 6 Yes | 27 No |
Post New Answer View All Answers
why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?
What is diffrence between extractable volume and deliverable volume? Answer pls
In BP2013, Loperamid HCl monograph. Assay by titration with 0.1N sodium hydroxide using hydrocloric acid 0.01N and reading the volume added between the 2 points of inflexion. I have a question that if the diluent solvent is ethanol is certainly consumed a amount of volume of titrant, so this volume must be eliminated on the result calculation or not apart from first point which is subtracted above.
how a particular wavelength can be different for a particular compund while analysing by uv and by HPLC.
effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?
Tell me something about Vitamin A test method by HPLC
I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?
iam usig ph buffers merk. manually how to prepare ?
Why dissolution test is not performed in all of the products
How to do regeneration of Metacarb Pb plus column?
In IR spectra, generally a molecule vibrates without apply emr or ir light?
is it necessary to do HPLC calibration at wavelength 315nm if we are doing analysis at this wavelangth
How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?
how to select short coloum and long coloumn for new molecule
if instrument calibration fails then what require to do?