Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

HOW MANY EARTHINGS REQUIRED FOR GENERATER

Answer Posted / rajeshsan

The earthing of Generator at star point is depends on the capacity.

For larger generators eg:- 600MW generator the generator is grounded using NGT and generator body is grounded at two ends. Earthing are done at two ends to have redundancy only.

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the formula for selecting the cabels according to load? How to calculate what sq.mm cabel to be used?

1431


what is the importance of earthing system on the generators big capacity and small?

1702


what happens when dc generator coupled with cycle shaft.also explain what happens when its loaded

2084


Transformer how to maintaince a check b check c check d check

2041


what happens if earth of 33kv cable is not connected to earthing pits? please send this query's answer to ngrm.sudha249@gmail.com

1975


why burdens of VTs is more than CTs?

1717


trasnfarmaer core make

1901


WHAT CAUSED THRESHOLD VOLTAGE TO EXIST?

3999


ult of expression 'document.FrmQF.myem

2013


difference between main metering kiosk and check metering kiosk

2933


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

742


What is EMC filter in VVVF Drive ?

2677


What is the requirement of grounding the neutral of single phase generators on load? If the neutral is not grounded, what will be the effect?

2063


Where voltage are high and current to be interrupted is low the breaker preferred is:

2229


what is model question rrb junior engineer electrical gr.II

1894