Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

1)What will you do if main incomer VCB fail in your site ?

Answer Posted / g.kumaresan.

If Main incomer fail in our site Immediatly to Isolate the
incomming supply and VCB. Bec's to protect the inside Heavy
Equipment insite in our site, then to inform the situation
in our Authoriy officer, at the same time to ensure the
back feeding arrangement, Bec's can not maintain the supply
intruption in long time.

So, doing back feeding arrangement immediatly with our
higher authrity knowledge and also other officer sugection.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to produsing geretor power

2190


describe the A.C. Generator Testing procedure

2155


I want definition for ABT Meter (Availability Based tariff) ?

1973


How to calculate the time setting for star connection in star delta starter? For example 10KW 3PH Induction motor.

2613


The moisture in air will condense at

1163


what is PID control in VFD drives?

1981


what is the ms flat constant for calculating earth mat design calculation?

2495


Is it required to use Automatic transfer Switch in L&T panel board if we use AMF panel with DG set? How the single line diagram will be? Please forward the material to sreenu_207@yahoo.co.in

4702


what is the use of the circle diagram

5564


if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit

1858


if i am in front of transmission line how to know that current direction without any equipment

1753


What is difference between start imitation and start interlock for 3 phase motor protection ?

2239


what is Insulation monitoring device. where it is used? (in switchgear room or control panel or in field equipment)

2148


List the disadvantages of constant k filters?

1651


How to convert 2 phase to 3 phase electricpower in induction moter?

2098