Answer Posted / balaji
APFC panel is for automatic power factor correction. in some cases of industrial applications the loading pattern of the entire network of the industry will change time to time. so if you connect a fixed compensation. it will not be in position to compensate exactly what is required. but in case of APFC panels you will have a microprocessor based relay which helps you to sense the load current instantaneously and the particular MC relay will hunt for capacitors to compensate and power factor improvement will be automatic.APFC is nothing but steps of capacitors connected to the contactor in turn connected to the breakers and relay.It doesnt require much of the manual support as of fixed compensation is concerned. Your power factor will be improved automatically, APFC will have a step by step compensation.
| Is This Answer Correct ? | 29 Yes | 9 No |
Post New Answer View All Answers
temp of cast resin 1500kva tx formerwent up to 138.c but came down very fast to about 100.c within 20 mins when load was reduced from 70% to 60%
Define filter?
WTA used cb?
i need the curve duty cycle and amper for (150 kva @50% dyty cycle) transformer turn ratio :19 and vin 400
what is interfacing in computer studies?
Please explain, how to test vector group of tranformer(Delta y1) . Thank
How u can give the overload setting to any motor protection relay for a HT motors with formula and Example?
solor panels arrange some angle,panel is flat fitted energy was produced or not why?
A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?
EXPLAIN THE WORKING OF SERIES REACTOR IN HT CAPACITOR BANKS (FOR VOLTAGES & CURRENTS)
What do you mean by turns ratio of instrument transformer?
what is the use of surge suppresser in 33 KV incoming panel. where it must be installed,inseries with incoming cable surge suppresser must be at incoming of the breaker are outgoing of the breaker
Hi I'm doing my MBA(3rd semester).I applied for the post of ET conducted by BHEL the last year.I cleared the written and lost in personal interview.Again I wrote the exam this time and cleared the written n yet to take the personal interview.Shall I disclose in the interview about my studies.What shall i say if they ask about my change from studies to job
The gauge indicates the number of amps, but what about voltage? How voltage rating (for wire or fuse) determined?
What is resistance of 50meters, 16sq.mm, single core copper cable?