Hod do u calculate cable size for underground laying and
the factors effecting/influencing it??
Answer Posted / madhav
While other answers are general procedures for selection of
cable, underground cable laying is different, AFTER having
taken the above factors into consideration.
The laying of underground cable should also consider the
permissible conductor temperatures, ambient temperature,
number of cores and mode of laying (single cores or
multicores), etc. The maximum current carrying capacity
also varies with the type of cables and its insulation
properties.
Cable laying is also of several types. In case of single
core cables, they could either be close together or
seperated by one diameter of the cable. That could also
cause differences in current carrying capacities.
In general, for a loaded 5 core cable when laid in ground,
the derating factor could be 0.7 times the rated current
carrying capacity of the cable.
Is This Answer Correct ? | 5 Yes | 5 No |
Post New Answer View All Answers
What is the lower limit of break-down voltage of converter transformer.
Plz tell me how we can find that particular company has vacancy or not
1.main parts of generator? what is used A-check,B-check,C- check? 2.what is FM200 system in data centers? 3.difference between pac,ahu?
what is the id1 & id2 setting in differential protection relay of CSPC?
hi everybody how to design string combiner box (scb) internal parameters like bus bar and spd (surge protection device and fuse which place to set that,and also bus bar one particular cross sectional how much heat generated and how much power loss tell me Clearly and briefly
what are the values of VRY,VYB,VBR,Vry,Vyb,Vbr,Vrn,Vyn,Vbn for Magenetic balance test of 100 KVA and 63 KVA Distribution transformer
what is d check in dg 1500kva
How can we calculate the transformer rating if the load calculated is 1000KW (11Kv Supply)?
In Electrical 'Single Line Diagram' cable nomenclature shows "2 X 1C X 630sq.mm to be provided for one incomer. The question is how many cable to be proved for one Incomer.
What is the criteria for selecting the voltage classes of an AC Induction Motor.The KW rating above/below which ht/lt selection is made may be provided in details.
what is magnetizing and demagnetizing current in generator and motor?
please write motor, transformer, Generator setting, fault level calculation of Tr.etc
what is the Earth Voltages in Power Plants, Sub-stations, Industries, Residential & Commercial Buildings.
what is the difference between earth leakage and earth fault?
How to know Resistance and Reactance value of main and aux winding of single phase capacitor start capacitor run induction motor to find capacitor value?