why we step down voltage level from 33kv to 11kv and 11kv
to 415v.Instead we can step down voltage from 33kv to 415v
directly using single transformer.

Answer Posted / gulshan goyal(knit->iitk)

distribution transformer energised 24 hours hence there
are continious core losses which in turn depends on
voltage.Hence to reduce core losses transformer is
energised 24 hours at lower(11kv) voltage.

Is This Answer Correct ?    12 Yes 18 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com

2160


Anybody know how schematic diagram for reverse power relay? RPR for generator protection

1661


what is the use of static frequency converter and static excitation equipment? and where it is employed? for what?

3041


Can i use the B-curve MCB instead of C-curve MCB

1596


Can you tell me more about pu systems (per unit systems )calculation in large power systems? how to get the base for voltage and power in generator, transformator and transmission lines?

1802






do any one help me to get "C" license,, i have doubts ,,, if mediators ter pls call me,, my no is 8056640042

1023


hr round

1662


I am a possesor of c licence from 1993. I forgot to renew during the year 1998. During that time I was working at TNEB to till date. Is there any possibility to get renewed? or to apply for a new one?

1602


where lt & ht capacitor used

1759


Define the three phase formula fuse.

1401


state working of halogen lamp?

1362


Why is better to have a minimum ceiling voltage of 250% than 160%?

1405


Which device is used for the source of emission of electrons in a crt?

731


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1655


List examples of voltage source?

609