Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between Isolator annd Circuit
Breaker.

Answer Posted / senthil kumar

isolator is a off load device ie we cant able to close the
isolator under onload condition if we close the isolator
under onload it will damage the isolator but breaker is a
device having high withstand capacity(the withstand
capacity is based on application)so we can able to open
&close the breaker under both onload &offload
conditions......and also while opening &closing under
onload arc will appears at the contacts. the isolator have
no special arrangement to extinguish that arc but in
breaker we have some special arrangement to extinguish that
arc.

Is This Answer Correct ?    42 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why mostly the HV side of transformer has Delta?

3218


When calculating the speed of a rotor required for a particular frequency of synchronous generator we use the equation 60f/p Is this p is the number of pole pairs of rotor & do we consider the number of pole pairs in the stator is 1?

1999


we have one oven for 12 zone we are installed ir lamp in oven we control load from thyrister and 0 to 5vdc so our zone no 8 getting bright in fraction of second so what we do.. Please answer

1735


What is essential to prove safe isolation of electrical circuit?

1074


which is the best institute for PLC,SCADA,DCS in hyderabad

2349


what is the relation between reactive power and power factor for the what is the limit of reactive power and power factor

2098


What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.

2038


What is the formula for calculating the Instantaneous Short Circuit & overcurrent for any breaker

2009


why 3 phase is converted into 2 phase using electronics circuit why not 2 phases are diresctly putted from the 3 phase transformer??

2185


What are the types of class b amplifier?

1090


What is the difference between security constraint unit commitment and security constraint optimal power flow?

1708


On a 6 KVA UPS we have to provide a DC MCB for Battery bank of 16 nos (12 V 42 AH). What Shall be the current rating of DC MCB ?

2648


What are the necessary solutions needed to be carried out on a malfunctioned earthing mechanism of a VACUUM CIRCUIT BREAKER.(TAMCO)

2010


in our all power plant have connected in grid and grid voltage and plant voltage is same, but as per as electrical concept the power will transmit from high potential to low potential but here altough same,then how power transmit from power plant to grid.

2334


why don't we use the generator as a motor? and what will happen?

1882