Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why SF6,VCB,Oil Ckt Breakers are use in HT Side need brief
information ?

Answer Posted / veeresh m y

SF6 Used in HT Side is Only the Main Reason is TO Avoide
the Heavy Sparks In the High Voltage Side.

Is This Answer Correct ?    13 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is 30-phase of transformer

2279


AL=0B9H,bl=75H, ADD AL,BL AL=____________? CF________? OF___________?

2649


How to design the earth grid for lightning protection in an industry

4625


Saving in copper achieved by converting a 2 winding transformer in to an auto transformer is determined by A voltage transformation ratio B load on secondary C quality of core material D size of transformer core

3115


please give me all the Alarm .Trip ,Safety Relays & Conditions of Chiller mail me on ashokbabunhce@gmail.com

1803


I have a reading off 1.5ohms at my mem my main c/b is rated at 40/6 amps in a domestic house and i was told to change it to a b curve c/b is this ok

1652


Can you please explain creepage distance in detail, for a 6.6kV cable head what must the distance be and how do you determine it?

2865


What is superposition theorem?

1169


while doing high potential for 11KV 3 core cable how much leakage current will obtain?, what will be acceptance value?

2855


whats the differece between Exd and Exe

4905


ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?

2006


1.dg on load alarm/stop alarm... 2.dg on load. piu alarm alarm kaise chek krte hai

1912


How Self works in DG set

1983


how we can set the IDMT relay.

2192


What is earth system using on the floater TN-S or TT. Iam not sure and what ICCP

1704