Describe your experience with analytical instrumentation?

Answer Posted / swati

At present working as Laboratory Executive in application &
Wet laboratory, working on AAS, GC, HPLC,
Spectrophotometer for the analysis of Soil, Air, water
(Ground, Surface, Sewage, Industrial effluents) as well as
pharmaceutical product. And report submission of samples.


• Work on multitudes of aspects in the lab apart from
analysis.

• Analysis of Volatile Organic Carbons, PCB’s, PAH,
Phenols, CO, CO2 using methanizer,
FAME analysis .
• Developed a perfect hand in utilization, handling
and maintenance of GC (All netel
manufacturing ), HPLC (Water TM 486),AAS
(PerkinElmer),UV-VIS
Spectrophotometer.(Thermo-Orion)
• Having a Knowledge of making S.S. Columns and
method development.

1.Analysis of Different Types of Raw Material, Tablets,
Syrup, Perfume, Injections, Oils etc.

Worked On :
 Gas Chromatography (MACRO 9100, Ultima-2100,
Analyte-2700, Platina, (All Netal GC)
 HPLC - Saif Water HPLC (Double Piston Pump)
 Water TM 486 Tunable absorbance Detector (Single
Piston Pump)
 IR: FTIR -410 Jasco

2.Gas Chromatography:
 Separation Of components from mixture using CHEMITO
8310 Gas Chromatograph
3.Spectrophotometer Mtd. Of s analysis:
 U.V. Visible Spectrophotometer (ELICO INDIA SL-
159), Visible Spectrophotometer (ELICO INDIA SL-171,
Colorimeter (ELICO INDIA), Polarometer, Nephelometer,
Florometer, Flame Photometer etc.
4.Industrial Chemical Analysis:
 Volumetric Analysis: Acidimetric, Alkalimetry, PPT,
Redox, Complexometric, Estimation of Industrial Chemical,
Ores, Minerals, Alloys & Oils etc.
 Physico Chemical Analysis: PH Meter, Conductometer,
electrolytic analyzer, Refractometer, Say Bolt
 Viscometer & EC-TDS Meter etc.

Is This Answer Correct ?    22 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in OSD forms require to use gas chromatography?

324


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1101


Loss of linearity in tkn analysis, possible reasons?

789


how you confirm the assay method?

279


how require to interprit the method precision data of hptlc?

285






What if impurity area in control sample coming more as compared to LOQ level of impurity ?

1131


in DMF having extra impurities and in api COA also having extra imp than USP or BP product then how require to proceed?

336


What is the difference between purge septum flow and column flow in gas chromatography?

1819


mahagenco syllabus for the post of chemist

5732


How do we quantify crystaline and amarpous forms by using (NMR, XRD)spectroscopic techniques? Which any others instruments are useful for this quantification? explain

1939


why require the ph, buffer during hplc mobile phase?

392


We use hicrome 10 cxs column in hplc analysis....pls tell me.. what is the meaning of 10 cxs?

1143


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

343


What is similarity factor and its use in api strength?

776


how you establish the LOQ?

293