Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to calculate the average power factor in 3 phase
unbalanced system

Answer Posted / razi zainal abidin

Dear all,
This is not an answer, actually question.

In one factory, we are dificult to measure resistance,R and
impedance, Z.

What we have is only voltage supply (3phase, 420volt), and
total current flow during maximum usage using clampmeter
(including machinery, lamp, computers, etc...)

We also have info of main transformer step down because it
is in the factory area. Normally they stated value of KVA.

And some factory already install the 'capasitor bank
regulator'

So, how we can calculate the CORRECT VALUE of capasitor
need to install?

I mean, which one is the correct KW, which one is the
correct KVA, and how to calculate existing power factor IF
the factory already have 'capasitor bank regulator'....can
we switsh of the regulator?

Is This Answer Correct ?    5 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the power factor used by the PHCN in nigeria? 2. what is the difference between an alternator and generator. 3. Generation of poweris in KV but how is transmission is in MW. 4.If the transmission of power is 20,000MW how can it be increaesed to 80,000MW

8614


What is the reason for using a GE G101 MCB in place of an EP102 MCB if both are capable of AC circuit protection?

2646


how we explain parallel paths armature winding?

1951


How to calculate the size of earth cable to earth the neutral of UPS ?

1933


if we look on phasor of the transformer vaoltage is 180 oppsite at primary and the secondary so to improve a power factor is secondary should kept negative to improve it primary side means is -.90 became +.90 at other side

1854


Explain the different methods used in the choice of rotor slots for reduction of harmonic torques in an induction motor.

2020


how is the cable tray designed & how its total length is calculated for an Industrial plant Say for Ex. (500KW Motor Load)

1892


Draw a SLD of DG distribution up to main LT panel?

9482


What is the difference between rulling span and wind span of of an Over Head Transmission Line?

2321


we have an energy meter in a capacitor bank panel, So should we consider it's readings as energy consumption on daily basis. (when capacitor bank doesn't have any energy losses)

2408


What is the dc grounding system and what is diff between AC/DC grounding system?

2116


control & auxilary circuits used for circuir breakers

1883


What is open delta Xformer? It's adavntages & Use?

2225


How does cost of generation from hydropower plant compare with other sources of electricity?

1050


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

1920