Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Do you know how to measure the earth resistance? if so
explain it

Answer Posted / natarajan

In this meter there will be four terminals(E, P1, P2, P3)
in which E and P1 will be shorted and connected to the grid
or electrode and P2 and P3 are reference electrodes which
will be kept on the earth surface on two different
locations for taking the reference resistances of the earth.

The meter shows the resistance of the earth. But it is
neccessary that it should be below 1ohm

Is This Answer Correct ?    24 Yes 15 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

l&t switch FN 63 handle position can we change

2507


how much cable size required for 70 kilowatt load.

1622


Why the power factor improvement is so important in industrial loads

1962


PLZ EXPLIN ABOUT CLASS PS CLASS CT .WHY THEY R DESINED AND FOR WHAT PURPOSE?WHY OTHER CT CANT BE USED AS PS CLASS CT? EXPLAIN IN SIMPLE LAUNGAGE IF POSSIBLE PLZ GIVE CIRCIT DIAGRAM?EMAIL-RAJ_SINGH_0376@SIFY.COM

2207


apti mainly on logical reasoning, verbal and non-verbal ability (70 percent) and remaining technical. I was in ee but technical had mech ques like on turbines and welding.

2131


I am having dual speed motor of cromton greaves make of 3.7 KW -1400 rpm and 5 KW - 900 rpm. Please let me know groups and winding connction for rewinding purpose.

1866


What is voltage divider rule?

1137


Starting times for soft starter & power factor is thier any standard or datas available in manufactures list. Kindly suggest.

1869


what is physical distance of isolator to VCB in 33/11kv sub stations

2071


When we have earthing mesh or underground earthing network in industrial plants, weather we have NT-S or NT-C-S kind of earthing system, so eventually weather we must use 4 or 5 wire in 400 volt level (For example 3×150+70 mm2 or 5×150 mm2) in this connection I would like to know exactly the paragraph of IEC or IEEE number

2100


why ct ,cvt should be stored in a vertical position?

2595


Why water bubbles when D.C. Current is passed through it? Why not when A.C. Current is passed?

2087


How to arrange a hous hold earthing system to keep minimum earth resistance( below 7ohms).

1893


How PSV sizing being done

2266


A Question Like A Wire Is Wound Whose Resistance Is Some 132. 44647 Ohms. If A Voltage Of 30 mv, 296 Ma Current Is Applied To It What Is The Resistance.

1020