Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

HOW MANY EARTHINGS REQUIRED FOR GENERATER

Answer Posted / nagaraj u.n

2.( body or frame) earthing should be used.because in case
of 1st point is faild ,2nd point is worked .it safety for
generator & opperatore.

Is This Answer Correct ?    2 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

HOW TO CHECK THE VECTOR GROUP OF A TRANSFORMER YD11?

3564


we are small scale industry in production of rice & rice bran. Pls let me know how to take contract demand for our industry.. (for information we have total 600.hp)

4272


Dears we deal in Chemical are Plate earthing. Kindly call if any requirement and questions. Tech Earth Solutions Mohit Verma 8791071007

1818


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2094


Please explain me abt PQ diagaram in the power sector.

2359


WHAT IS THE TOTAL POWER GENERATION IN CHHATTISGARH?

1898


how to calculate the formula of cable size if motor kw is given

2181


Why the dc voltage drop during starting of emergency lube oil pump? The Voltage drop from 135kv to 125 kv for one min. before re-establish to 135kv?

2255


how does high earth to neutral voltage affects electronic circuit?

1863


How do we calculate transformer oil in liter from the rating of the transformer.

1604


What is the permissible maximum flux density in transformer core?

1189


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to reconfirm its base capacity.

1937


What happen to the transformer if the OLTC frequently used for lower and raise occured 50times daily?

1981


trasnfarmaer core make

1900


what is the difference between neutral and earth

2012