What does negative slip of an induction motor signify?
Answer Posted / satya
For an induction motor we have
s= (Ns-Nr)/Ns
so slip can be negative in the region where the value of
rotor speed exceeds that of the synchronous speed. usually
while working as an induction motor the speed of the rotor
cant touch the synchronous speed. because as it does so
there will be no cutting of the flux lines by the rotor
conductors. so there will be no emf induced so no current ,
so no force and no torque.
but when the induction motor is run by an external
primemover over the synchronous speed now rotor speed
increases that of the Ns. so rotor emf E2> stator applied emf.
the induction motor now functions as an induction generator.
| Is This Answer Correct ? | 65 Yes | 2 No |
Post New Answer View All Answers
is this the formula of building wiring to get the main breaker.Watts/volts*.8%+higher motor*(25%)=ampere. yes or no or send the correct formula for building wiring.
how to work droop ct in generating station
explain which quantities change in the starting and the and the running condition in induction motor
why it is not advisable to run low rating (19KVA) DG sets in parallel for long durations even though they are provided with droop ckts (QDC)
Mention the disadvantages of low power factor? How can it be improved?
which VFD is better ( LT or HT)
hi this is hema can anyone mail me previous years questions for the APPSC-A.E.E (in electrical stream.) ......thank u.
I'm looking for a mnaual set for a Teradyne J750. Softcopy would be preferred but I'll take what I can get.
where solid grounding and where grounding through ngr done and why?
What is kirchoff ’s current law (kcl)?
is it true there's a big difference in using Cummins or Denyo...especially power output or leakage
what is the advantages of having in-built acvvvf (without seperate inverter in the control panel)in the drive system of elevators?
which type of amplifiers are used in multimete?
A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.
How to define Kirchhoff current law and voltage law along with simply examples.