why earthing is not required on transformer prymary winding
side ???
Answer Posted / jackson
If the primary side of the trasformer is delta, then only
body earth required.delta no eathing is required because
upstream is delta circuit which increase the reliability of
power transmission if earth fault occur. in delta circuit,
no earth fault will be detected.
| Is This Answer Correct ? | 14 Yes | 2 No |
Post New Answer View All Answers
I want formula to calculate current loss with distance in km.I searched many sites but didn't right answer.Plz reply me
What do you mean by lighting transformer?
What do you mean by pull of electromagnet?
What is effect of harmonic current (Draw by VFD) on power system/ electrical Equipments ?
what is the transformer turn ratio formula and give some examples?
what is booster? and how it is connected in a circuit?
In DC generator, we use commutator, having no. of segments. Then how it is possible to get a half wave of voltage and current for half rotation of armature?
Enlist four components of electrive drives.
What are the advantages of hydropower?
How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?
If any one's require of phoenix contact like( relay , termilnal block , surge protection device ) , product please contect me 09878206357 chetan verma
What is the RMS and DFT principle of analogue maesurments. Which way they are advangages. where which princples give optimum results.
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
substation+ plc system
what is mean by Digital Logic Meter (DLM)