what are the types of sus station ?

Answer Posted / rvg.msceb

These are main types of sub-stations.
1.at generating stations: step up voltage to higher level
2.at intermediate stations: step down voltage to lower level
say 400Kv to 11kv, and power factor improvement may be also
doing within these sub station

3.At load center: Where voltage is getting down to 400volts,
and this is near to be load center

Is This Answer Correct ?    12 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If two Transformers are connected in parallel having impedance of 50KA in both transformers will the impedance increase or decrease after connecting transformers in parallel?

1540


what are the possible reaons & remedies if resistance of NGR getting heat up

1388


what is the meaning of neutral displacement ???

2251


why and how voltage sharing in transformer, during magnetic balance test ?

1804


how are reversing the direction of rotation of dc motor

1260






What is polar plot?

706


mccb service sittings be done?

1363


What is the resonant peak?

645


Whether amorphous core transformer is available in India?.If available then up to what rating of voltage and KVA?.

1300


what is interpose? where it is used and why it is used?

629


Leakage current,un balance current which relay using for high voltage transmission?

1632


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1362


what is the eight bit unit?

1964


in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply

1569


how can you size an automatic voltage regulator?

1867