how can u correct the error in loading for Delta failure
Answer Posted / hari
we perform repeat delta, for delta failure. the process
involves setting the technical status to red in monitor
screen, deleting the request in the requests tab of
infotarget/manage and then scheduling the delta load
normally. there will be an alert that the repeat delta is
being performed, its ok and proceed to load the delta. this
brings up the old delta records and any of the newly added
delta records.
| Is This Answer Correct ? | 20 Yes | 3 No |