Answer Posted / sa
First, take a clean wire loop of Platinum or nickel-
chromium . They may be cleaned by dipping in hydrochloric
or nitric acid, followed by rinsing with distilled or
deionized water.
Test the cleanliness of the loop by inserting it into a
bunsen burner flame. If a burst of color is produced, the
loop was not sufficiently clean.
Ideally, a separate loop is used for each sample to be
tested, but a loop may be carefully cleaned between tests.
The clean loop is dipped in either a powder or solution of
an ionic (metal) salt. The loop with sample is placed in
the clear or blue part of the flame and the resulting color
is observed.Na+ plus gives dazzling golden yellow flame,Ka+
gives crimson red & when look through blue glass gives
purple colour. Ba salt gives apple green colour , Ca++
gives brick red colour,etc
In this way Flame test is done.
| Is This Answer Correct ? | 18 Yes | 3 No |
Post New Answer View All Answers
if peak get problamatic then what require to do?
IS THERE ANY EQUIPMENT TO CHECK AND CALCULATE THE POLARITY OF A LIQUID?
cefoperozone and sulbactam inj. hplc test method
Loss of linearity in tkn analysis, possible reasons?
what is mean by covalidation
What is Band broading effect explain
what are risk assement in the analytical qbd?
how to calibrate hplc & gc
how to qualify the impurity?
please explain about aluminium hydroxide assay
Ph meter can show more than 14 ph reading? Why ph range in between 1 to 14 only?
In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?
Principle of single pan analytical balance
WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?
which batch require to use for analytical method validation?