Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between CT for protection and Ct for
metering?

Answer Posted / minal

ct for protection means that current transformer is used to
step down the higher values of current to lower values
which is to be measured by the instruments.Thus it protects
the equipment from damages.
ct is also used to measure the low values of current.This
is how it is used for metering.

Is This Answer Correct ?    14 Yes 124 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the criteria that generally follow by distribution licenses to fix contact demand of their industrial customers?

1522


it is possible to rotate the DG engine dc starter with wrong polarity connections? why?

2255


What is the effect of interchanging core(made of steel) and winding(made of copper) material in case of transformer? Give proper explanation in regard to different losses in transformer.

1879


How will polarity test of Dy5 Transformer ?

2271


Brushes are placed at magnetically neutral axis,when brushes reach that point,the armature conductor gets shorted,but it can be seen that the dc supply is also shorted,wont that get damage? help me plz

2295


is it possible to say motor horsepower number without seeing name plate(when name plate damaged)

5360


How to calculate KVA/VA rating of PT or CT from primary & secondary voltage or primary & secondary current?

2426


hai friends i have BSNL JTO exam on next month so if any body have model question paper or give preparation tips to my mail id kumar4486@yahoo.co.in this will helpfull for my future .plz & thank u by kumar

1989


why we use circuit breakers for switching instead of normal switching device?

1876


Efficient electrical earthing in hard rock area

1572


why +24 v and -48 v give to BTS? If -48v protect from surge then why we not use -24 v?

1840


What are PLC leader logic program method

1767


Is it possible to connect a safety device in to parallel?

2156


why the frequency and voltage in india is 230v and 50HZ. when compared to USA say 110v and 60 HZ.

1446


How impulse levels are calculated that for 11kV impulse is 75kvp, for 24kV impulse is 125kvp ?

2001