Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to check the 3ph capacitor is good or not.

Answer Posted / sa

if the capacitor connected in capacitor bank switch off all
the capacitors except the capacitor want to test if thepf
decreasing at the moment capacitor is not good .

never short the terminals .........

Is This Answer Correct ?    14 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the voltage gain or transfer function of amplifier?

1089


What are the different towers used in 132kv transmission line? what are the differences between the P,R,S towers used in 132KV and detailed explanation

1844


What is the formuala to calculate the rating of motor protection circuit breaker

2166


The transmission does not have options: a)Partition noise b) Flicker noise c) resistance d) Short noise and reason

2383


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2094


I need bhel electrical test pattern & paper

1790


Define noise?

1110


Why open circuit test of transformers is conducted at rated voltage??Why not any other voltage??

1616


what is vtg limit of earth and neutral at transformer side?

1978


why output is out of phase in case of common emitter?

2094


how to Select its CORE in electrical cables based on its applications? or Application of various types of electrical cable based on it CORE?

3196


what is there inside an inverter and how it works?

1773


excitation limit of an excitor

1985


EXPLAIN THE WORKING OF SERIES REACTOR IN HT CAPACITOR BANKS (FOR VOLTAGES & CURRENTS)

8197


what are the difference between PLC and embedded

2087