What does negative slip of an induction motor signify?
Answer Posted / trupti
slip=(Ns-N)/Ns
wh Ns - sync speed
N - actual speed of rotor.
generally whn IM is acting as motor,rotor speed is always
less than Ns,but if it is acting as gen(a prime mover moves
rotor),N bcms gr8er than Ns.
hence 4m formula we can c that s bcms -ve.
it implies rotor is running faster than stator field.
| Is This Answer Correct ? | 29 Yes | 3 No |
Post New Answer View All Answers
What is the abbreviation of NGT panel
Why slip ring ind. motor power consumption is low compare to induction motor .same 90 kw motor used same load output
why transmission is only 3 phase and not 2 or 4 or poly phases
hi can any body send me syllabus of rrb electrical section engg... and past pepar also of any board...
What is K-rated transformer? What is the use of it? What can be the size(pls provide calculation if possible) of K- factor transformer for 550kW,690V motor operating with drive (VFD)?
What is the difference between rulling span and wind span of of an Over Head Transmission Line?
What is vaccum currcuit breaker.define with cause and where be use it device?
how many stairs have you climbed while you were coming
How to determine stage of Automatic Power factor controlling Relay(Apfcr)?
- two pumps must work with them at the same time but if the first pump start the second pump must delayed for some time to start also , with motor rated power = 90 KW and rated voltage = 380 V and rated power factor = 0.85 lag please draw the power and control circuit for it and determine all circuit components parameters that you use it
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Please define ohm’s law for a.c (alternating current)?
Sir, I have applied for the of Assistant.engineer of NPDCL. please send me all AP TRANSCO AND JENCO solved papers of previous exams . I requested send me the papers to my id as soon as possible (rajanikanth_peddi@yahoo.co.in) (This is very urgent) Thank You,
what will happen if ac and dc supplies given
why only exciting current is shown not primary current in transformer???