in dc shunt generator field is open in running condition
what will happen?
Answer Posted / v.karthikeyan
If the sunt field of the Generator got opened the Back EMF
will be drastically reduced and there will not be flux
linkage between the armature field and sunt field.Hence
output voltage will not be as sufficient as stipulated.
| Is This Answer Correct ? | 14 Yes | 4 No |
Post New Answer View All Answers
if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.
HOE WE CAN IMPROOVE BY USE OF CAPACITOR
Describe the test procedure to determine the vector group
What is the polarization index value ? (Pi value)and simple definition of polarization index ?
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
what is conductor constant of raccun conductor
what is dc mator?types of dc motor?losses in dc motor?what is the mechanical,electrical and commercial efficiency of a dc motor?
ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?
is it possible to say motor horsepower number without seeing name plate(when name plate damaged)
Why earthing is necessary for any equipment?
How to calculate the multiplying factor for energy meter with ct ratio given
formula for calculation of switchgears(i.e. contactor, fuse, cb, relay etc.), if load current is given?
How can we increase the capacity of Energy.?
If the rated speed of a d.c. Shunt motor is1440 r.p.m, which method of speed control would you suggested to obtain a speed of 1500 r.p.m?
how can I calculate charging current of cable/overhead conductor? what is roll of voltage in it ?