Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


disintigration time of coated tablets

Answers were Sorted based on User's Feedback



disintigration time of coated tablets..

Answer / anuj gupta

30 mins

Is This Answer Correct ?    16 Yes 12 No

disintigration time of coated tablets..

Answer / matta sravana lakshmi

for enteric coated tablets 2 hours or more in simulated
intestinal fluids and 1hour in gastric fluids

Is This Answer Correct ?    29 Yes 26 No

disintigration time of coated tablets..

Answer / amiya ranjan panda

foR un coated tablet-NMT 15 MINS.
FOR FILM COATED TABLET-NMY 30 MINS
FOR ENTERIC COATED TABLET-2 HR DOES NOT EFFECT IN 0.1 N HCL ,WITHIN 1 HR IN PHOSPHATE BUFFER ,
FOR SUGAR COATED TABLET-WITHIN 1 HR

Is This Answer Correct ?    3 Yes 0 No

disintigration time of coated tablets..

Answer / afzaye rasul

1.uncoated NMT 15min
2.Film coated NMT 30min
3.sugar coated NMT 1hr
4.Enteric coated :2hrHcl+1 hr buffer PH-6.8

Is This Answer Correct ?    2 Yes 0 No

disintigration time of coated tablets..

Answer / bharath nagalapuram

uncoated tablets: 15mins
film coated tablets: 30mins
sugar coated tablets: 60mins
enteric coated tablets: should not disintegrate for 2hrs in 0.1N Hcl and should disintegrate in phosphate buffer 6.8 within 1hr.

Is This Answer Correct ?    4 Yes 3 No

disintigration time of coated tablets..

Answer / meena

nmt 30 min.

Is This Answer Correct ?    3 Yes 2 No

disintigration time of coated tablets..

Answer / vivek sagar

Uncoated tablets :- NMT 15 Min
Film coated :- NMT 30 min
Sugar Coated :- NMT 60 Min
Enteric Coated :- NMT 2 hour
in 0.1 M HCl & 2 hour in 6.8
PSO4
Dispersible Tabs:- within 3min
Effervescent :- 5 min
Buccal & Sublingual :- 15-30 min

Is This Answer Correct ?    1 Yes 0 No

disintigration time of coated tablets..

Answer / akash ameta

Uncoated- Nmt 15 min.
Film coated- Nmt 30 min.
Sugar coated- Nmt 1 hours
Enteric coated- 2 hours
Dispersible and soluble - 3 min.

Is This Answer Correct ?    1 Yes 0 No

disintigration time of coated tablets..

Answer / nimesh trivedi

disintegration is the breakdown of tablet into granules &
the time taken for this is known as disintegration time.
for uncoated tablets-NMT 15 min.
for film coated tablets-NMT 30 min.
for sugar coated tablets-NMT 60 min.
for enteric coated tablets-NMT 120 min.in gastric fluid media & 60 min.in buffer media

Is This Answer Correct ?    0 Yes 0 No

disintigration time of coated tablets..

Answer / s.prasanna kumar

sublingual tablets with in 5 sec
uncoated 5min
film coated 15min
sugar coated 1 hr
enteric coated 2hrs in stomach & 1 hr in small intestine

Is This Answer Correct ?    2 Yes 6 No

Post New Answer

More Pharmacy Interview Questions

What is the formula for KF standardization?

2 Answers  


how FTIR calibration Doing?

4 Answers   Dr Reddys,


How impurity is analyzed in any tablet?

1 Answers  


Why we use pyrene in HPLC calibration ( UV-vis/PDA)

2 Answers   Lupin, MSN, MSN Pharma,


What should be the sampling point in dissolution test?

1 Answers  


Why we said Glacial Acetic Acid to Acetic Acid m

0 Answers  


define the starting material?

0 Answers  


what is the defintion of Pka?

7 Answers   Reddy Labs,


what is difference between uniformity of content and content uniformity as official test for tablet

0 Answers   Eskom, Hetero,


how to select HPLC column for a particular product

0 Answers  


Describe how you would educate a patient about the proper use of Alprazolam, including dosing instructions, potential side effects, and the importance of follow-up appointments.

0 Answers  


when we calibrate uv for control of wavelength we scan for 200 to 800 nm but we get the result only for some specific wavelength how we confirm for all other wavelength?

0 Answers   Strides,


Categories