why transmission line 11Kv OR 33KV,66Kv not in 10kv 20kv?

Answer Posted / pankaj rajput

The answers mentioning the form factor 1.1 are correct.

Just one clarification...

1.1 is form factor of a Sine wave...hence ac voltage being
a sine wave holds Form Factor of 1.1

Is This Answer Correct ?    71 Yes 27 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is transient enclosure vltage , very fast transients, very fast transient over voltages

1626


working principles of cf lamp,incandescentlamp and f lamp?

1826


Dear Sir/Madam, I have one questions we have three steam turbines and one Gas turbine and our industry linked with the public network, we have protection system one of the protection is reverse power we can export just four MW only i would like to ask about how to calculate the reverse power. Thank you in advance best regards

1627


What is center gravity load in substation?

1919


Details about Flux Compensated magnetic Amplifer starter for motors

1584






What is the Resposiblity of Electrical Utility Engineer

2405


how we decide wire gauge for ac or dc coil and what is the basic diff. B/w these two coil?

1656


What is the safety of UPS?

1274


sir i have cleared the apti test of EIL held on 15th march and my interview will be in new delhi on 2nd june.i will be very much helpful if u help me regarding the type of interview questions comes at EIL.(URGENT.........PLZZZZZZZZZZ...............)

1552


why booster transformer is used in sumpners test conducted on transformer????

3070


What is meant by stator?

648


how to calculate current carring capacity of cable and cable selection? 1) copper flexible cable 2) copper armoured cable 3) Aluminium cable

1049


When a single pase capacitor run motor- run on 230vac and Case(1)run with 8 Mfd 250 vac.capacitor , Case( 2) run with 8 Mfd 400vac capacitor. What is difference between both case regarding power ,efficiency etc?

1638


How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.

1254


hi all i like to know vat is power plot in control systems also i want to know abt latest trends in electrical & electronics

1446