Why we use Carbon & graphite mixxed brushes in the DC motor?
Answer Posted / prasad
THE PURPOSE OF CARBON BRUSHES ARE TO POLISHING THE SURFACE
OF THE COMMUTATOR AND TO REDUCE THE REACTENCE AT THE
COMMUTATOR.
Is This Answer Correct ? | 6 Yes | 6 No |
Post New Answer View All Answers
Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?
which cable is used for 15 Hp monoblock pump 3phase and service wire Distance is 210 feet please tell me cable size Armaured
Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?
Why space heater is required for each verical bus bar chamber? if one space heater is adequate or not for anti condensation?
why dc is used in control circuits for MV & LV switchgeras instead of ac
What is difference between slip rings and carbon burushes?
what is harmonics? what are the factors it will depend upon
How do you select the pickup value of the relay?
is there any lightning by passer is arranged in ship like buildings?
how does the rotating m.m.f is produced in the 3-phase induction motor and how the poles are created in 3-phase induction motor ?
A ray hit a smooth regular surface at an angle of 20 from the normal. Calculate : 1. The angle btw the incident and reflection ray. 2. The angle of deviation.
what happens if dc supply is given and the remedies for it.
The Howland current source produces a A Unidirectional floating load current B Bidirectional single-ended load current C Unidirectional single-ended load current D Bidirectional floating load current
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.
HOW DO I CALCULATE THE SETTINGS FOR THE DIFFERENTIAL PROTECTION OF A 12kV/6.6kV, 6MVA,DYN11 XMER WITH PRIMARY SIDE CTR 400/1 AND SEC SIDE CTR 600/1?