Rotor is taken away from three phase induction motor and
three phase supply is given to the stator.What will happen?
Answer Posted / himanshu misra
A rotating field will be developed.
| Is This Answer Correct ? | 11 Yes | 2 No |
Post New Answer View All Answers
Which motor will you choose which can operate in both lagging as well as leading power factors?
Dear sir, In our plant have Station Transformer having capacity,i want to know, why LV side 40 - 40MVA is given? & how we can get 6.3 KV supply from tertiary(i.e. Open delta connection), Vector Group YNyn0 - yn0 +d MVA Rating 80MVA / 40 - 40MVA + 26.7MVA Voltage rating 420 (Tap range +6,to -10)81.25% /11.5KV - 11.5KV +6.3KV
i want use the cable size 16cx4 core aluminium usege watts 240x2000w this cable size is correct?
What are the main parts of central chiller plant? Explain the function of each stage.
salam&hi, i need to know about how can i calculate an enough current for the new building before i submit it to the suppliers
If two Transformers are connected in parallel having impedance of 50KA in both transformers will the impedance increase or decrease after connecting transformers in parallel?
How to calculate phase to phase difference ?
How much pf maintan in dg set in 6o% load,when Dg runnig Neutaal Earthing removed what happen.
What is the Good Earth resistance value of G.I & Cu. Chemical Earthing & Normal Pipe Earthing?
regarding safety what would u consider the most important rules to observe when inspecting electrical equipment?
what is the working principle of energy saver control panel. please give the complete calculation & theory.
What is the working principle of MIG welding? and its out put Voltage?
what is the pre charge circuit,what will be work which function it will be use plz tell me
what is Insulation monitoring device. where it is used? (in switchgear room or control panel or in field equipment)
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.