we re giviang 24v supply to transmitter and we getting
output from tx?now my question is wht we call this complete
proces?

Answer Posted / hiren

As output is seen from tx. It is open loop system . If tx stands for controlling application it is closed loop system.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the difference between profibus and controlnet networking.

2593


Im having problems with interfase betwen SPI v7.0 and SPPID v5.05. Previous versions of Intools shoul be fixed with SPPIDproj.ocx file. It was necessary to replace this file with one that allows the connection between different versions of SPPID. It is necessary in the current version to do the same?Thanks

1869


In bently nevada vibration monitoring system,what is the reason to maintain the Resistance of the probe + extension cable equal to 95 ohm? If possible explain the basic principle of measurement with detail electronic circuits.

2497


What is difference between Ionization heat and bimetallic heat

1153


Definition of reverse and acting controllers:

1842






What are primary elements of measuring pressure?

770


In VVVF DRIVES VOLTAGE IS ALSO VARY WITH THE FREQUENCY. HOW? WHAT IS THE DIRECT FORMULA RELATING THESE TWO.

1901


How signals can be taken through modbus?

692


what is surge and how is it prevented, what is the purpose of bypass valve across AS valve.

1569


Give Detail information about plc,dcs,and scada system?

1271


principle of dead weight tester ?

1608


Define the difference between a stable versus an unstable controlled system and some of the tools you might use to be able to detect when this is happening and assumptions used for control system application design that could contribute to instability

1396


what is 24vdc live and dry supply

1823


what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?

2076


Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer

4178