why synchronization done in clockwise direction?
Answer Posted / p.anandsah
It doesn't matter if you synchronise TG with Grid in cw or anti cw . Just after synchronisation increase the power as soon as possible.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
how to calculate the tarriff for an industry whose kva demand is 10 mva
we specify current in case of feeder but in case of distributor voltage, why?
how generator load test is conducted?what are the steps?
A 230V dc shunt wound motor has an armature resistance of 0,15Ω.When operating on no load at 650 rev/min the armature current is 6A . The motor takes a full load current of 85A. Calculate the full load speed if the field flux is (i) maintained constant (ii)reduced by 0,03
In parallel operation time both NGR’s close or not close if both close what will happen
How can a equal potential zone be carried out in conductors?
What is the function of electron gun assembly used in crt?
how to find three phase complex power in per unit and MVA?
what is the difference between unarmoured & Flexible cable? How to identified?
WRITEDOWN FEW RELY CODES
What is the mechanism of WTI
At what speed 1 HP motor can run an electric car of weighing 400 kg?
what are the sample questions asking to the test cunducting for electrical superwising lisence test?
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
Hi everyone, I'm Lachuu, recently joined automation company as PLC Engineer. I have certain basic question, I request all big gurus and seniors to answer these question. Because this will be very helpful to me as well starters like me. How to design a control circuit (ex: pick & place - my current project) Yamaha robot PxYx series controller RCX222, using 6 cylinder double acting, plc keyence kv p16r 2 expansion unit for input and output each. How to select panel terminal mcb elcb powersupply. My main concern in some projects how to select dc power supply, mcb rcb(I came across dif bt b c d curves, but stil confusing, pls help me :-(. I would really appreciate all who are going respond to this question.