inductive power factor is benefit compare to capacitive????
Answer Posted / arul
We are using maximum load for industrial and commertial also the inductive load because the current has been laging then voltage. Because we need to compensate the effects while we are using capacitive pf correction use to correct the power factor
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
difference between power surge and switching transient
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
hi frnds...pls send me aptransco previous papers .....pls..pls,,,(madhar.rocking@gmail.com)and suggest me some websites
Why the standard of ambient teperature mentioned as 40 degree celcius in machines.
why the active power flow of some line is increased when the active power of out is cut ?
Why are short circuit ratings always 16kA,25kA,36kA and 50kA.Who has fixed these?
how many Classification of fire extinguisher
how to calculate the change over time for star delta starter for different KW motor?
In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.
Which types of gate insttaled in static switch. Please give me answer.
Why do not we prefer non conventional sources of energy to conventional sources?
Explain the propagation of harmonics in the network and influence of phase angle of harmonics.
What is the Resposiblity of Electrical Utility Engineer
Use of switch mode power converter in real-time basis?
in Telecom DC system-why positive +ve is made earthed.and - ve is fed to load.