difference between shunt coil and tripping coil

Answer Posted / ravishankar.ck

There are to methods of tripping the MCCN, ACb, VCB or SF6 one is Shunt trip operated by DC voltage or AC Another is Series trip works or current
with small voltage developed by CT which does not require any auxiliary supply coil and trip coil As it the shunt trip must be tripped with auxiliary supply this can also be used for tripping during the fault using protective relays. The relay will sense the voltage or current excesses beyond preset value through CT/PT and gives a xommand to shut trip coil and trips breaker LT, HT or EHT

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What will happen if the d.c. Shunt motor opened accidentally running on no-load has its shunt field winding?

893


i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test

1382


Why neutral cable carry current.

1522


What is the transfer function?

624


static chagre

1705






The windings of a transformer are divided into several coils, because?

816


How each of the following losses occur in d.c machines (i) copper (2)core (3) windage (4)friction please help me

1597


Where can I get Iidian straderd specifications for electrical items or works in web? please help me.

1588


Dear all, i completed M.E(Power Electronics & Drives) 2011 passed out having 78% so i need job in core side but i don't know how can i receive the calls from electrical companies and i uploaded my CV in naukri, times jobs etc.. In that iam not recieved any mails from good companies so give me best procedure plzzzzzzzzzzzzzzzzzzzzzzzz..... Thanks, K.Linga Reddy Email-id:-lingareddykmthm@gmail.com Ph no:-08015402078

1407


i am completed my degree(B.E EEE) 2014 anychance to get electrical licence plz help me

1671


how to measure dc earth leakage current?

2600


WHAT IS THE SIGNIFICANCE OF VECTOR GROUPS IN TRANSFORMER? WHAT WILL BE EFFECT WHEN PHASE DISPLACEMENT CHANGES IN TRANSFORMER?WHAT IS THE NEED TO BE PHASE SHIFT CHANGE BETWEEN THE PRIMARY AND SECONDARY WINDING

1340


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1366


what is the voltage regulation for unity and zero power factor?

1764


1. How many types of mangers? 2.How many types of capacitors? 3.pls tell me normally types alternator problems?

1721