if AVR fails in D.G set, what will be the effect?

Answer Posted / nishad

Failure of AVR means AVR will not deliver the excitation voltage to the exciter stator winding. Hence, Exciter stator winding will not be able to generate any magnetic flux and there will be no any field voltage generate in exciter rotor winding and it will not feed any output voltage to rotating diode assembly. If the diode assembly fail to get the supply, it will not supply the voltage to the main rotor winding which used to make the main flux between main stator and main rotor, and as a result main stator winding will not generate any output voltage even if the DG continuous running.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the advantages of stationary armature and rotating field system?

704


what are the interview question asked in wind mill about electrical

1927


I have motor 1500 HP and , 4160 V , 60 HZ , then i need the rating of transformer which can feed that motor ??

1403


Dear sir, iam completed iti ncvt electrician 2000-2002 & diploma electrical eng completed 2008-2010 distance education in rvd university, still i got B licences only but my working company want C licences, how to i get c licencese pls reply me iam in critical situation thank you karthick 9841637803

1267


What are the advantages and disadvantages of short-pitched winding?

605






What do you mean by an instrument transformer?

654


The simple way of finding the leakage quantity and % in compressed air distribution system

1204


For some transformers we are using solid neutral earthing while some others we are using resistance earthing why ?

1472


bus bar design conditions and sizing pls tell me quickly

1489


How phase to phase voltage comes 440V.

1456


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1658


Explain the operation principle, advantages and disadvantages of the following converters: a) A 12 pulse converter b) A Switch-mode inverter c) A thyristor inverter

1498


Pl.brief me about Electrical power distribution system from Main generating station to Industry.What is the use of in between station.

1597


Explain how you intend to work under pressure to meet up with deadline target?

4720


HOW WORK HEAT PLATE EXCHANGER

1528