why secondary of transformer always grouded?

Answer Posted / santhan kumar reddy nareddula

To my knowledge , in order to protect the load which is on secondary side of transformer, we usually ground it

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is an Air COmpressor

1712


I want to know all basics of electrical engineering

1430


Can anyone please give me the parameters , formula needed to calculate the circuit breakers for building services.Thanks

1671


The transmission does not have options: a)Partition noise b) Flicker noise c) resistance d) Short noise and reason

1933


How I calculate the ELCB for circuit breakers?

1655






what is difference between isolation and ultra isolation transformer?, what is the method of testing ?

3827


In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.

1124


Is it true online ups having bypass mode if it is true then why we called ups because it is interrupting power when goes in bypass mode

1541


Whar is the KvA rating of 33Kv substation & actual kv rating of power generaating station.

1879


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1337


What type of DC motor would you see for a lift?

641


if voltage bt phase & nutral is 38v in a panel board . whats the root cause.

1808


limitation of conductor height on ground when we consider EMC

1488


What is routh hurwitz stability criterion?

643


May I know how much values to be set for earth fault, over current and short circuit values at 11kv side? I have 11kv van 1250amps rating. Present it's taking load 80amps?

1017