How Arc Extinguish in Minimum oil circuit breaker and What is
the function of Radial and axial vents of turbulator in
Minimum oil circuit Breaker Where these vents are exists.

Answer Posted / tushar choudhuri

Rated interrupting time is the mean time for interruption of any current exceeding the rated interrupting current of the Breaker.The possible relaying time of modern high speed protection is 0.5 to 1,0 cycle.The breaker interrupting time of high speed modern circuit breaker is nearly 2 to 3 cycles.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Hi everyone, I'm Lachuu, recently joined automation company as PLC Engineer. I have certain basic question, I request all big gurus and seniors to answer these question. Because this will be very helpful to me as well starters like me. How to design a control circuit (ex: pick & place - my current project) Yamaha robot PxYx series controller RCX222, using 6 cylinder double acting, plc keyence kv p16r 2 expansion unit for input and output each. How to select panel terminal mcb elcb powersupply. My main concern in some projects how to select dc power supply, mcb rcb(I came across dif bt b c d curves, but stil confusing, pls help me :-(. I would really appreciate all who are going respond to this question.

1510


briefly explain the main blocks found in a microprocessor based system

1717


How to calculate approximate load loss of a distribution transformer by knowing %ge imp of transformer?

1748


What are the uses of stepper motor?

725


Define characteristics impedance?

673






Why the earth to phase voltage is high 250 compare to other two phases

1061


Dear sirs, pls check this 4-20ma to RS485 module datasheet,pls guve me some suggestions. http://www.szsunyuan.com/sy/pro_more.asp?Productid=539 Thanks. E-mail:yunianjiang99@gmail.com

1681


How shall i select the value of capacitor or inductor in a system?

1452


What is VSCF windelectrical system?

1352


What are the necessary components of the feedback control system?

732


testing of Vector Group – YNaoD II

2461


Explain using drawings what is reverse PID action w.r.t PID controllers.

2759


11kV capacitor bank of rating 2.4KVAR, is charged with protective relays of only over current & Earth fault &.......without Over Voltage, Under Voltage & Neutral Displacement Relay. Is it advisable??

1200


HOW TO CALCULATE CAPACITOR BANK OR HARMONIC FILTER CALCULATION

1790


gas turbine genrator reactances

1527