What is min and max voltage between earth and neutral/phase
if it perfect earthing?
Answer Posted / nitin pathak
Normally in case of single phase supply the phase and neutral comes from 3 phase power supply (one of the 3 phases).also as normally single phase supply is given to smaller appliances it's body is connected to earth and the neural is earthed at the source or transformer end.Now due to cable length of the neutal wire a voltage drop occurs and when measured we get a voltage between earth and neutal.Even if the neutal is connected to a perfect earth at the supply end due to cable resistance we receive a voltage drop.also note that the neutal earth is different from the appliance earth and you will always get a voltage drop between earth and neutral.If the voltage is zero between earth and neutral then it has been deliberately shorted and it should not be done as we do generally.also maximum 2.5% of rated votage is the neutral voltage
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
What is the comparison between 30mA DP RCCB and 100mA DP RCCB and can replace it against 63A MCB
IF TVM OF TRANSFORMER SHOWS POWER FACTOR ON 33 KV SIDE AS 0.97 LAGGING AND ON 132 KV SIDE IS 0.75 LEADING.IS THIS CORRECT.WHERE IS PROBLEM.
what is interfacing in computer studies?
what are problems caused by the pdu in rack server
Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above
1)What is a Triode? What are its uses? 2) What is a Triac? 3) What is a Thyristor?
how dose servo motor works
Sir, I have applied for the of Assistant.engineer of NPDCL. please send me all AP TRANSCO AND JENCO solved papers of previous exams . I requested send me the papers to my id as soon as possible (rajanikanth_peddi@yahoo.co.in) (This is very urgent) Thank You,
what is the main parts of transformer? how it is functioning? pls giv the ans briefly.
When calculating the speed of a rotor required for a particular frequency of synchronous generator we use the equation 60f/p Is this p is the number of pole pairs of rotor & do we consider the number of pole pairs in the stator is 1?
How do we calculate transformer oil in liter from the rating of the transformer.
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
what is the difference between electrical and electronic choke?
What is use of starter and choke in tube light
gas turbine genrator reactances