Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In control valve there are two type of valve seat we can use
metal to metal seat & soft seat.On this valve seat i have
following doubt.

1)I have never seen practically the internal assembly of
valve so my doubt is that basically weather the seat is soft
seat or metal its basic MOC is same as valve body(SS or CS)
only in soft seat we are using PTFE ring & place on valve
seat & in metal this PTFE ring is not threr am i correct???????
2)what are the common general rule for using metal to metal
seat & soft seat,means its depend on process parameter like
liquid,gas, steam & on valve leakage class.

Answer Posted / mrinal

Ball valves operating up to a process maximum temperature of 200 deg. C shall have soft
seats, unless specified otherwise in the project specifications. Beyond this temperature,ball valves or isolation valves shall have metal seated.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How process line mpm calculation is done?

1423


what is droop in governer ,type of droop ,how it work

2157


How does your previous experience relate to the job you are applying for ?

2024


What are the materials available to prepare individually for competetive exams in Instrumentation field? Plz reply...

2095


How can i copy program (parameter) from mm440 (V.F.D.) by using BOP?

2732


What is the working principle of the magnetic meter?

1141


all questions related to instrument technician in any offshore oil and gas company.

21677


Drum level tx with GP4 with zero elevation:7300mmh20 on HP and 8050mmh2o on LP as range but on commissioning the tx readiing is max,Why this reading?

1938


what is the responsibility of an instrument commissioning supervisor

3165


Actual using of tube bender to bend 2 opposite 90 deg at correct measurement center to center of tubing.

1896


A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

2179


Draw a simple circuit for a well head control panel used to protect the well against fire, leak, blockage, ESD, & controls the operation of one downhole & one surface safety valve. Explain the operation and controls

1643


find the kp ki kd from the transper function G(S)=29.44s+04707/1.5349s2+s

1940


How to calibrate Magnetic flow Transmitter in Field

1278


For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?

5464