Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

The insulation resistance of a cable can be measured by

Answer Posted / deepikawalde

A very significant maintenance procedure for checking out the working condition of an electrical system is called IR test or Insulation resistance. It can be said that ht system or equipment is fine when insulation resistance is high.
Megger is an insulation resistance measurement tools for finding the equipment’s insulation resistance. Let us see how is the IR calculated?
Define Insulation resistance
There is an application of direct current (DC) and not alternating current (AC) and this is the first thing while doing the Insulation resistance test. for more :- http://crbtech.in/Electrical-Training/index.php/2017/07/31/define-insulation-resistance-and-its-calculation/

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How does "OUT OF STEP" relay ,for Synchronous motor protection, work?

4350


Is it required to use Automatic transfer Switch in L&T panel board if we use AMF panel with DG set? How the single line diagram will be? Please forward the material to sreenu_207@yahoo.co.in

4740


What are the weight of 800KV DA,DB and DC type tower ?

3148


Why electrical power generation and transmission done in 3 phase system not more than 3 phase ?

3082


how to control dc motor?

1923


What is formula calculation size cable wire ?

1959


What is the automatic voltage regulator with servomotor?

2044


What is T’Q and X’Q and X’D ? and what is saturated as well as unsaturated ?

1795


WHAT IS FAULT CAPACITY OF HT MOTOR TERMINAL BLOCK? ANY BODY HAVE ANSWER PLZ....POST IT.

2198


what is POTT and PUTT explain?

3363


State the factors, for the choice of electrical system for an aero turbine.

1172


What is fault clearing time for Current Limiting Moulded Case Circuit Breaker?.

1786


Define cut-off rate?

1093


What is an ideal transformer?

1183


FOR 16/20 MVA 132/33 KV ONAN/ONAF TYPE TRANSFORMER IT IS DESIGNED FOR 16 MVA WITH ONAN CONDITION.IT BECOMES 20 MVA UNDER ONAF CONDITION.LOAD LOSS IS GUARANTEED FOR 65KW AT 20 MVA AND % IMPEDANCE 13.75. PLEASE TELL US AT WHAT LOAD LOSS AND % IMPEDANCE IT SHOULD BE DESIGNED FOR 16 MVA AND WHAT WILL BE ITS EFFICIENCY AT 20 MVA?

3407