in steel bar weight formula (d^2/162).so what is 162.

Answer Posted / ankit panchal

Weight of bar = d^2/162 x lenghth of barfor 1000 mm (1 meter) length Reinforcement rod
Weight = Volume X Density
Weight = (Area x Length) X Density
Weight = ( Pi/4 x d^2 x Length) X Density
= (3.14/4 x d^2 x 1000) X 7850
Density of steel is in Kg/m^3 & Length is in MM
So Lets Convert Density of steel KG/m^3 to MM (7850 / 1000x1000x1000 (i.e. m^3) )
= (0.785 x d^2x1000) X 0.00000785
= d^2 x 0.00616225
Lets assume 1
= d^2/1 x 0.00616225/1
Let reverse
= d^2 / 1 / 0.00616225
= d^2 / 162.278
Say d^2 / 162

Is This Answer Correct ?    9 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is Short bored pile foundation.

2201


What is the outturn of Ceiling plastering

2860


Can anyone suggest how to determine scheduling of reinforcement of floor beams from Staad model,other than clicking each beam respectively 7 noting down the values ?

1652


During reclamation how can the occurrence of mud waves can be rectified?

831


detailed calculation of the amount of cement used?

1634






how to control PQI (Project Quality Index)

9844


3. A vane 12.5 cm long, 8.8 cm dia was pressed into a soft clay at the bottom of borehole. Torque was applied and the value at failure was 55 N-m. find the shear strength of the clay on a horizontal plane.

1635


HOw much % of premium on DSR-2013 currently

1544


can you give me the details of rate analysis of steel and concrete?

2470


Explain why concrete barriers have curved surface profiles?

825


foundation details for 25 ton weight Furnace on 2 supports and 2 tilters

1113


how much of the strength comes from post-production curing

2270


how to do cementicious paint for rcc walls of cw pump house

1549


what is the difference between natural draught cooling tower and induced draught cooling tower

1826


What is bylayer?

686