Answer Posted / asmoorthi2000@gmail.com
RTU is a Remote terminal Unit which is reflecting the present status of the equipment in the SCADA. So an operator can do the controlling function of the equipment from the SCADA. Normally in a substation, the feeder status will show in the SCADA through the RTU so operator can do the open/close any breaker in the feeder by SCADA through RTU
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
how to avoid electrical shock how capacitor store charges wat are the speed control of induction motors state faradays law flemings left hand rule what is rotary converter wat is transmission and distribution what are the sources of energy abrevation of acb,vcb,sf6,igbt what is output equation of transformer which test copper iron and iron loss are calculated what is eddy current draw a single line diagram (10 marks) draw direct online starter(10 marks)
How vfd saving power.
how to check regenerative load in drived motor
State how to produce a constant rotating field by application of alternating currents to stator armature of a three-phase squirrel-cage induction motor
What are hrc fuses and where it is used?
What should be the amps for a MV fuses for transformer 630kVA 20(10)/0.4 kV
Is there any rule to select the voltage of motor based on KW rating? What is the rating above which lt motor becomes the HT motor?.
what is draiv work
at what basis/standard we have to arrive the current density of aluminium/ copper in busbar?
- two pumps must work with them at the same time but if the first pump start the second pump must delayed for some time to start also , with motor rated power = 90 KW and rated voltage = 380 V and rated power factor = 0.85 lag please draw the power and control circuit for it and determine all circuit components parameters that you use it
we have consol make 3 phase servo stabilizer for cnc m/c. while installing the earth neutral voltage is 1.7 volts at stbilizer off condition and when stabilizer get on en voltage reaches 4.8 volts (new earthing is done and neutral is helthy condition all phase to neutral volts 440,442,441 v)why this happen.solution for cause.
1.WHAT IS A SMART CAPABLE DB ( DISTRIBUTION BOX) ? 2. HOW TO DECIDE THE TYPE OF DB TO BE USED ( RECESSED/ PLUG TYPE/ SMART ETC ETC? 3. WHAT IS MILLENEUM BUS BAR USED IN DB? 4.DIFFERENTIATE MCCB AND MCB.
How to Calculate The sag of OPGW in Transmission Line???
I WANT TO know WHICH WAY IS BETTER FOR CONNECTION BETWEEN POWER TRANSFORMER AND MAIN DISTRIBUTION PANEL. 1-IS BETTER WE USE CABLE? 2-IS BETTER WE USE BUS DUCT? my transformer rate power is 2500KVA
what is earthing.how we make it,describe briefly.