What is cv of control valve

Answer Posted / faiyaz ahmad

Cv of control valve means co efficient of valve
Cv capacity of valve

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

anybody having Qatar Petroleum questions for instrument Technician offshore ....please send me

5563


How process line mpm calculation is done?

847


What is standard procedure of manual mapping in Radar type level transmitter?

1425


How to Calibrate Temperature Switch in field

801


What is the basic difference between Modbus and CAN Open Protocols

5818






I have completed B.E. Instrumentation & control in 2009. i have 3 year industrial job experience in chemical plant.now, I want to join M.E. in external. so, Plese say easiet way and good institute name.

1474


how the arrangement of equipments done in control room

1592


what is instrument philosophy

1750


If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?

1030


Sir, I am working as a Instrument Engineer in Grasim Industries. Can any body provide question answer for interview purpose

1676


please someone tell me what is function of vibration sencer and how many types and how to control viberation.please. my id is jimmykhan077@gmail.com

1366


what is the procedure for auto tune in masoneialn 12300 series displacer type transmitter?

1218


Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72

1652


 why Fahrenheit unit of moistur analyzer transmitter

1789


We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

1142