why not phase to phase fault occure in raining day in hv sub-station?
Answer Posted / ankitshah55
Because rain drops are not continuous. Only in rare cases if rain is full than not only LL but LLL fault can also occur. But in transmission lines the design and slag plays the important role. Also insulators are designed so that water cannot accumulate.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
What is Primary And Secondary Injection Test of Relay and Other Electrical Devices. How IT is carried out.
I want to make street light with solar system ... What may I do for procedure and how much of estimation for each material ... If any one knows guide me and inform this id : aravindd7@gmail.com
why we r not earthed Control cable of C.T. terminals
Where I can get the sample question for post of Junior engineer electrical-II For RRB Bhubaneswar.
Can the output voltage of a rectifier be greater than the input AC voltage without the use of any voltage multiplier in the circuit??please provide the explanation too..
WANTCONTACT NUMBER & EMAIL/ WEBSITE TO CONTACT THE SECRETARY,MADHYA PRADESH LICENSING BOARD(ELECTRICAL),K- BLOCK,3RD FLOOR,SATPOODA BHAWAN,BHOPAL
briefly explain principle of resistance welding
What will happen if we introduce negative feedback to a control system that uses a positive feedback?
is it value of power factor is more than unit. whats effects in the source supply
if there is nutral in phase why we use earthing wire and grounding? even at fault condition the fault current flows to neutral (it is a lower path)
DC transmission
Why does the Solid state Rectifiers for 3-ph brake motors sometimes have 2 & sometimes 3 output terminals?
Why the power generated in dams is complex power? Why the generators in dams cannot produce Real power directly (i.e power which has zero reactive part)?
If o/p power is doubled by how much does the sound increase