Question 88 - In the calculation of the growth of bacteria, colony forming unit (CFU) in serial dilution is used. In a laboratory, viable count assay is used to estimate CFU. Formula applied is CFU / mL = (number of colonies x dilution) / (amount plated, in unit mL). Acceptable plate count is either between 20 and 200 or between 30 and 300 according to 2 different references. A wastewater sample of 200 ml is added to and mixed with 1.8 L of sterile water. Another 200 ml of the mixture is added to and mixed with 1.8 L of sterile water. (a) Calculate the dilution of first mixture and the dilution of the second mixture. (b) 100 microlitres of wastewater samples from the first mixture and the second mixture are placed separately on 2 different alga plates. The first plate has 250 colonies and the second plate has 23 colonies. Calculate the average CFU / mL.
Answer Posted / kangchuentat
Answer 88 - (a) Dilution = (final volume of mixture) / (initial volume of mixture). First dilution = ( 0.2 + 1.8 ) L / (0.2 L) = 10. Second dilution = first dilution x ( 0.2 + 1.8 ) L / (0.2 L) = 10 x 10 = 100. (b) 100 microlitres = 100 microlitres x 1 mL / (1000 microlitres) = 0.1 mL. CFU / mL = (number of colonies x dilution) / (amount plated, in unit mL). In the first plate, CFU / mL = 250 x 10 / 0.1 = 25000. In the second plate, CFU / mL = 23 x 100 / 0.1 = 23000. Average CFU / mL = (first plated value + second plated value) / 2 = (25000 + 23000) / 2 = 24000. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Plz if anybody has placement paper of HAL mail me i m Chemical engg my id er.kotnala@gmail.com
marketing procedure of iocl
What is a good device to use for obtaining viscosity data for a non-newtonian fluid?
repected sir i have given gate exam today.......... if i ll get the better rank in that ....what is the next process .....shall i give another one test......or wat....i dint get properlly..... plz help me or mail me on Nish_gasti@yahoo.co.in
MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)
What is a solvent?
Explain the different ways in which solids can be blended?
Define octane number?
What are the advantages and disadvantages of using gear pumps?
need the type of technical questions in written test
print a pattern of abcdcba abc cba ab ba a a ab ba abc cba abcdcba
How does a cyclone separator work?
The process conditions of the fuel gas are as follows: Temperature = 25 deg C Pressure = 4 bar g Calculate the line size for the fuel gas supply line to the superheater
What is the wet bulb globe temperature (wbgt)?
What is a quick way to calculate frictional pressure drops in carbon steel pipe?