What is BMS System???Types...

Answer Posted / naveen joshi

BMS is bacnet (building automation and controll network) based system .running via Ethernet in main controll device (router station) and lon/talk in branch device(DDC Controler station).ethernet can handle 10 to 100mb data, while lon/talk up to 75kb data. Entire system divided in segment through router station .a analog to digital converter or digital to analog placed in between computer software and ethernet connected router station to operate ,monitor the hvac ,power substation and fire system.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1370


Can we check ELCB constantly from R1 to R8 phase in 1 no DB?

1226


What are the classifications of heating element?

1527


how to design coil turns ?

1538


what are the problems that generally occur in power flows??

2553






what is interpose? where it is used and why it is used?

635


what will happen reduce the transformer voltage from 415v to 406v, is it save the energy,? are this methodis good to reduce the energy.?

1102


If we impress a dc voltage of 230 V on an unloaded 230 V, 50 Hz transformer it wi A give high secondary voltage B burn out C give secondary voltage as per K D none of these

1580


If rotor works in clock wise what happens

1450


What are the weight of 800KV DA,DB and DC type tower ?

2708


how to make an earthing certificate

1770


What is mean by spike arrester(Voltage Operated)

1612


What the difference between three phase contactor (coil 110vac) & three phase SSR (control voltage 110Vac)? May I use contactor in place of SSR?

1653


explain working principle of earth leakage relay

3077


what is ATS & RING MAIN UNIT in Distribution System?And its Function.

1508