What is the safe limit of voltage between earth and neutral in india.
Answer Posted / sheikh
Between neutral and protective earth voltage should be zero. while between neutral and system earth voltage should be not exceed more than 3 volts
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
How to calculate capacitor bank value to maintain unity power factor with some suitable example?
what is meant by loss of field in a DC motor? how a universal motor works?
what is sevice settings for mccb?How can be it setted?
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
Does the motor power displayed on the Motor name plate is the mechnical power motor delivers or it is consumed power from the system?
WHaT IS THE CONCEPT OF INDUCTION LAMPS IN MODERN LIGHTINGS, and HOW IT WORKS TO EMIT LIGHT ( AS NO ELECTRODES ARE PRESENT ) ?" COULD INDUCTION LAMPS CAUSE INTERFERENCE WITH COMUNICATIONS INTO A STORE USING INDUCTION LIGHTING ? WHAT IS THE BENEFIT OF USING THE LOW FREQENCY INDUCTION LAMP , VERSUS LED , AND VERSUS FLUORESCENT, AND VERSUS ANOTHER KIND OF LIGHTING . THANK yOU MOISES GUINDI
how can check the resistance of battery contact?
Explain about how is it working Earth fault'relay and wahts the resistance value of earth bed
what is the terminal voltage of dc series generator running at rated speed at no load?
why single CT used in DOL starter power circuit?
How to findout raw or ups power? its not indicated in socket,
how to check three phase motor torque value?
What is warm / cold start of HT motors. How many warm start & cold start are possible in a day?
What descriptive information does the NEC require to be marked on all conductors?
WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.