WE ARE HAVING YOKOGAWA CENTUM CS 3000 DCS, 2 FCS AND 4 HIS "
When the operation Download to HIS message appears:
Equalize start. HIS0163
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. HIS0163
---- ERROR = 3 WARNING = 1 ----

Tell me, please, why and how to solve the problem."

Answer Posted / jaguirre

Dear Prashath,
Just found your solution here in this website.
Can I asked for other possible solutions. All 5 items you gave was checked and verified but still, i'm not able to equalize.

Thanks and hoping for any suggestions.

Regards,
John

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Describe the function of Accumulator into the Pump

1483


What is the working principle of the magnetic meter?

630


hii my name is sujith...i am preparing for HPVL GET 2010... so ,,,pls help me by send any previous questions or material to my site.....(Msujith_12@in.com) thank q

1460


few questions on RS 232,1 question on relationship of impedance and turns ratio, many questions on flowmeters

1607


Instrument QA/Qc what is the project quality plan?conduit inspection RFI. which documents attache with package?

10400






For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?

5004


Give an example where you had aproblem on the job, and tell me how you solved the problem. and the finalvoutcome.

1809


what do u mean by compensation n pid tunning?in pid tunning what you tunned?is it possible 2 tune p i d

4371


we have level transmitter for h2s04 storage tank capacity 10k ,always there are failure of transmitter due to failure of magnetic floats ,please come up with solutions at the earliest.

1596


how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.

2015


while am calibrating Drager polytron 2IR flame gas detector occured non zero status.how can i get zero status?

1706


what is the difference between attemperator and desuperheater ?

4986


what is gas metering system? gas chromatograph? and gas compressors?

1964


How works weighfeeders in cement industry? what is the working principle?

1523


What is the use of double seated valve?

733